Chamber Furnaces
Heavy Duty Burn off Chamber Furnaces up to 1100 ˚C, Heated volume 8.5 and 10 lt
BOX-CW10-1100 chamber furnace family designed to serve under the most demanding burn off, ashing/combustion applications environments. This muffle is Ideal choice for wax removal and presents an every day partner for professionals working in dental, jewelry or other similar areas.
- Maximum Continuous Temperature 1100 ˚C.
- Kanthal FeCrAl embedded resistors.
- Available models heated volume 8 and 10 litters.
- Heavy duty model. Constructed with seamless, hard, glass-like refractory with embedded resistors provides the highest degree of protection against harsh gaseous environments, molted metals splashes and carbon or other deposits.
- Heated from four sides of the chamber performs excellently in terms of temperature uniformity.
- Furnace Chamber Protective Atmosphere (up to two flow control systems).
Key Features
- Best available quality KANTHAL® FeCrAl wire wound resistors insure furnace long life operation.
- Control strategy based on Thermansys® PCC (Power Consistent Control) platform insures silent operation and compliance with EMC (Electro-Magnetic Compatibility) standards.
- Economical performance under daily thermal cycling.
- Accurate and uniform temperature profiles.
- Modern double wall construction keeps external surfaces temperature low, emphasizing in operator safety. Internal skin is exclusively made from stainless steel to enhance durability.
- Ergonomic design with no protruding edges, bolts or other features combines stainless steel parts with painted finish parts for an improved esthetic result.
- USB and Ethernet ports for connection to a PC.
- Touch Screen 4.5΄΄ Computer embedded running PYROLOGISM software human-machine interface.
- 3 user process thermocouple inputs available (B, E, J, K, N, R, S, T type- software configurable).
- Power and true RMS Current measuring circuits.
- Heater failure, open control thermocouple detection alarms and interlocks. Alarms and events front panel led array.
- Alarm event output (dry contact 3A/250V AC/DC).
- USB client B type and RJ45 port for connection to PC.
- Stand alone over-temperature limiter (Watchdog) with manual reset in accordance with EN 60519-2 to protect the oven and load. Overrides main controller and cut off heater power if user adjustable high limit is reached.
- Lift up door keep hot surfaces away from operator.
- Threaded ports facing the heated chamber at the rear panel for Thermocouple probe installation.
Specifications
Standard features:
Optional features:
CE Certified. Compliant with Low Voltage Directive 2006/95/EC (harmonized referenced standard EN 61010-1: 2001 and EN 61010-2-010:2003) and EMC Directive 2004/108/EC (harmonized referenced standard EN 61326-1:2006).
Produced in GREECE following ISO 9001:2008 quality management system and ISO 14001:2004 environmental management system.
- Maximum continuous temperature 1100 ˚C.
- Operating Power: 208 /240VAC – 50/60Hz.
- Two in depended K type embedded thermocouples for controller and over-temperature limiter feedback.
- Temperature control accuracy ±1 ˚C.
- Embedded resistors type.
- Thermocouple inputs: 3 chan. - B, E, J, K, N, R, S, T type- software configurable, 24 bit A/D conversion, 0-45°C cold junction compensated, Typical accuracy ±0.2% f.s @ 25 , resolution 0.1 °C.
Optional features:
- Flow controllers:
Number of lines: 1 or 2
Line 1 gas type calibration: Air
Line 2 gas type calibration: Nitrogen (N2)
Flow range: 0.01-20 std L/min
Accuracy: ±2% of reading for Air, ±3% of reading for N2
Typical Control stability: ± 0.1 std L/min.
Temperature (0-50°C), Pressure (0-15 psig) comp.
Filtration: Not provided, user supplied HEPA grade.
Line 1 gas type calibration: Air
Line 2 gas type calibration: Nitrogen (N2)
Flow range: 0.01-20 std L/min
Accuracy: ±2% of reading for Air, ±3% of reading for N2
Typical Control stability: ± 0.1 std L/min.
Temperature (0-50°C), Pressure (0-15 psig) comp.
Filtration: Not provided, user supplied HEPA grade.
CE Certified. Compliant with Low Voltage Directive 2006/95/EC (harmonized referenced standard EN 61010-1: 2001 and EN 61010-2-010:2003) and EMC Directive 2004/108/EC (harmonized referenced standard EN 61326-1:2006).
Produced in GREECE following ISO 9001:2008 quality management system and ISO 14001:2004 environmental management system.
Models
For detailed ordering and technical information please see our technical brochures:
Maximum Temperature 1100 °C, Heated Volume 8.5 and 10lt
Doc No. BOX-CW10-1100 November 2016
Maximum Temperature 1100 °C, Heated Volume 8.5 and 10lt
Model No | Max. Temperature (C) | Heated Volume (lt) |
BOX-CW10-V8.5-1100 | 1100 | 8.5 |
BOX-CW10-V10-1100 | 1100 | 10 |
Doc No. BOX-CW10-1100 November 2016